Tipp Umwelt- und Verfahrenstechnik GmbH - Obere Hilgenstock 34 - DE-34414 Warburg - +49 5641 7447-0

Contact

Phone
+49 5641 7447-0
Fax
+49 3212 7447-280
E-Mail
e-mail to us

used used membrane filtration device, pilot plant - 29875 - Typ: FT-NF-x-2540-40 - Producer Fumatech - TIPP Umwelt- und Verfahrenstechnik GmbH

used membrane filtration device, pilot plant




details to article: 29875

HINWEIS: Dieser Artikel wurde bereits verkauft.
Klicken Sie hier um ähnliche Artikel anzuzeigen.

description: Mobile test plant for reverse osmosis or nanofiltration processes. The pilot plant can be easily converted at any time.

Producer:Fumatech
Typ:FT-NF-x-2540-40
Year of manufacture:2004
Pieces:1
Condition:gebraucht / used / second hand



technical data

Volume flow rate  0.2 m³/h (permeate flow max)
Volume flow rate  0.6 m³/h (circulation flow)
Pressure  45 bar (working pressure max)
Type of connection  380 V / 50 Hz / 1,1 kW
Accessories  (Leroy Somer frequency converter SKBD200110 / 240 V. / 60 Hz / 1.1 kW)
  (HYDAC pressure switch EDS 300 / measuring range 16 - 600 bar)
  (HYDAC temperature switch ETS300 / measuring range - 30 °C - + 150 °C)
  (IFM Electronic level sensor LR8000 / Switching point accuracy (15 + 0.5 % MEW**))
  (MITSUBISHI Frequency converter FR-S 520 / 50 /60 Hz)
  (ZUWA Pump ; Type: MT71B4 - STD ; 0,37 kW ; IP 55 ; 1380 1/min)
  (piston pump CAT Pumps 0.6m³/h ; 50bar)
Material  - (pump 1.4401, frame 1.4301, piping 1.4408)
Dimensions  (length 1400 / width 1000mm / height 1580mm)
Weight  170 kg
Video 
Filmtec Membranes SW30-2540


Artikel nicht mehr verfügbar

Einige, ähnliche Artikel aus unserem derzeitigen Lagerbestand

Nr.:28335
gebrauchte Hochdru...

informations about: reverse osmosis

Reverse osmosis (RO) is a membrane-technology filtration method that removes many types of large molecules and ions from solutions by applying pressure to the solution when it is on one side of a selective membrane. The result is that the solute is retained on the pressurized side of the membrane and the pure solvent is allowed to pass to the other side. To be "selective," this membrane should not allow large molecules or ions through the pores (holes), but should allow smaller components of the solution (such as the solvent) to pass freely.

In the normal osmosis process, the solvent naturally moves from an area of low solute concentration (High Water Potential), through a membrane, to an area of high solute concentration (Low Water Potential). The movement of a pure solvent to equalize solute concentrations on each side of a membrane generates osmotic pressure. Applying an external pressure to reverse the natural flow of pure solvent, thus, is reverse osmosis. The process is similar to other membrane technology applications. However, there are key differences between reverse osmosis and filtration. The predominant removal mechanism in membrane filtration is straining, or size exclusion, so the process can theoretically achieve perfect exclusion of particles regardless of operational parameters such as influent pressure and concentration. Reverse osmosis, however, involves a diffusive mechanism so that separation efficiency is dependent on solute concentration, pressure, and water flux rate. Reverse osmosis is most commonly known for its use in drinking water purification from seawater, removing the salt and other substances from the water molecules.
Osmosis is a natural process. When two liquids of different concentration are separated by a semi permeable membrane, the fluid has a tendency to move from low to high solute concentrations for chemical potential equilibrium.

Formally, reverse osmosis is the process of forcing a solvent from a region of high solute concentration through a semipermeable membrane to a region of low solute concentration by applying a pressure in excess of the osmotic pressure.

The membranes used for reverse osmosis have a dense layer in the polymer matrix where most separation occurs. In most cases, the membrane is designed to allow only water to pass through this dense layer, while preventing the passage of solutes (such as salt ions). This process requires that a high pressure be exerted on the high concentration side of the membrane, usually 2–17 bar (30–250 psi) for fresh and brackish water, and 40–82 bar (600–1200 psi) for seawater, which has around 27 bar (390 psi) natural osmotic pressure that must be overcome. This process is best known for its use in desalination (removing the salt and other minerals from sea water to get fresh water), but since the early 1970s it has also been used to purify fresh water for medical, industrial, and domestic applications.

Osmosis describes how solvent moves between two solutions separated by a permeable membrane to reduce concentration differences between the solutions. When two solutions with different concentrations of a solute are mixed, the total amount of solutes in the two solutions will be equally distributed in the total amount of solvent from the two solutions. Instead of mixing the two solutions together, they can be put in two compartments where they are separated from each other by a semipermeable membrane. The semipermeable membrane does not allow the solutes to move from one compartment to the other, but allows the solvent to move. Since equilibrium cannot be achieved by the movement of solutes from the compartment with high solute concentration to the one with low solute concentration, it is instead achieved by the movement of the solvent from areas of low solute concentration to areas of high solute concentration. When the solvent moves away from low concentration areas, it causes these areas to become more concentrated. On the other side, when the solvent moves into areas of high concentration, solute concentration will decrease. This process is termed osmosis. The tendency for solvent to flow through the membrane can be expressed as "osmotic pressure", since it is analogous to flow caused by a pressure differential. Osmosis is an example of diffusion.

In reverse osmosis, in a similar setup as that in osmosis, pressure is applied to the compartment with high concentration. In this case, there are two forces influencing the movement of water: the pressure caused by the difference in solute concentration between the two compartments (the osmotic pressure) and the externally applied pressure.
From Wikipedia, the free encyclopedia

email: mail@tipp-international.de
Internet: www.tipp-international.de

individual advice

We are characterized by experience and competence. Whether simple container units or large waste water treatment plants - put us to the test and we will gladly convince you of our services!

contact

You want to contact us? It's quite easy:

+49 5641 7447-0

We look forward to your questions and comments.

dismantling

Is does not matter - dismantling, decommission or relocation. We support you as fulfillment service supplier with specialist firms

article search

simple article search or professional search. Our search engine is very easy to handle. Find here your used plant/component.
...article search

re-purchase option

Buy and test! Profit from our fair and favorable conditions. Just ask.