HINWEIS: Dieser Artikel wurde bereits verkauft.
Klicken Sie hier um ähnliche Artikel anzuzeigen.
Ultrapure water system with reverse osmosis with softening
details to article: 29525
description: The system is used for the desalination of drinking water for demineralized water treatment for circulation systems.
- Average throughput: 300 l / h permeate (deionized water) / 20 l / h permeate feed.
The system consists of the main smoke
- Pre-filter 10 ", 5 my
- Softener (brine tank) with 10 "filter 5 my
- Reverse osmosis system GEO 20/75
- Control RO 1000 Falk
- UV disinfection in the bypass
- PP tank with heating for permeate feed and return
- Mixed bed filter cartridges
- x RO pump / 1x centrifugal pump distributor pump
- UV lamp (30 watt)
- Connections: 2x sink / city water / return and sewer
- Dimensions: L 1800 / W 800 / H 1750
- Operating hours: 34870
Producer: | Enviro Falk |
Typ: | RKA 300 mit GEO 20/75 |
Year of manufacture: | 1999 |
Pieces: | 1 |